Test
Used for traditional general purpose applications, where a non-polar column is required.
Max. Temperature | -60°C to +300°C (isothermal or programmed) |
---|---|
Type | Capillary GC |
Packing Material | Poly(dimethyl siloxane) |
Diameter (Metric) Inner | 0.53 mm |
Polarity | Non-Polar |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 1.5 μm |
USP Type | G1, G2, G9 |
Product Line | SPB |
Use Thermo Scientific™ TracePLOT TG-BOND Alumina GC Columns for linear and quantitative analysis of polar unsaturated hydrocarbons.
Max. Temperature | Up to 200°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Alumina |
For Use With (Application) | Polar Unsaturated Hydrocarbons Analysis,GC for Unsaturated Hydrocarbon Isomers,Linear and Quantitative Analysis of Polar Unsaturated Hydrocarbons |
Choose these colums that feature a popular GCMS phase for many applications.
Stationary Phase | Trace™ TR-5 MS |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Separate ethane, ethylene and acetylene consistently with the intermediate polarity PLOT column with essentially no particle release.
Max. Temperature | Up to 250°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Q+ |
Polarity | Mid-Polar |
For Use With (Application) | GC for the Separation of Ethane, Ethylene, and Acetylene to Baseline |
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
Max. Temperature | 340/360°C |
---|---|
Stationary Phase | TraceGOLD™ TG-XLBMS |
Polarity | Low-Polar |
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |
Greater stability and inertness at elevated temperatures and when working with highly active compounds.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MT |
Polarity | Low-Polar |
USP Type | G27, G36 |
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Max. Temperature | 330/360°C |
---|---|
Polarity | Mid-Polar |
USP Type | G42 |
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Polarity | Mid-Polar |
---|---|
USP Type | G43 |
Thermo Scientific™ TraceGOLD TG-VMS GC Columns provide good resolution and fast analysis times for volatile compounds.
Max. Temperature | 260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-VMS |
Polarity | Non-Polar |
Provides low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS.
Max. Temperature | 260/280°C |
---|---|
Stationary Phase | TraceGOLD™ TG-1301 MS |
Polarity | Mid-Polar |
USP Type | G43 |
Use these columns for a higher phenyl content that provides useful elution order and retention time changes.
Max. Temperature | 300/320°C |
---|---|
Stationary Phase | TraceGOLD™ TG-35 MS |
Polarity | Mid-Polar |
USP Type | G42 |
Use these columns for GCMS applications that require more polarity than a 5% phenyl column.
Max. Temperature | 300/320°C |
---|---|
Stationary Phase | TraceGOLD™ TG-17 MS |
Polarity | Mid-Polar |
USP Type | G43 |